Abstract :
An electrical system is said to have a high level of reliability if it is capable of supplying electrical energy continuously and in accordance with user needs. The quality of electrical power can be disrupted by the use of non-linear loads, such as computer devices, electronic devices, and energy-saving lamps. Harmonic problems in power quality arise due to the interaction between the sinusoidal waves of the system and the characteristics of non-linear loads, such as those found in the Computer Laboratory of the Samarinda State Polytechnic, which results in high harmonic current values. To determine the actual conditions, electrical parameters were measured. The results of the measurements showed a total current harmonic distortion value of 33.65% in phase R, 15.85% in phase S, and 92.99% in phase T. The individual current harmonic distortion in phase R decreased from 28.39% to 4.53%, to 3.76% in phase S, and to 2.63% in phase T on Thursday at 15:00 WITA. To overcome this, the use of a Static Var Compensator (SVC) is proposed as a solution to reduce the level of harmonics in the electrical system at the Computer Laboratory of the Samarinda State Polytechnic. The simulation was conducted using Matlab R2023a software through the Simulink feature. The results obtained show that the Static Var Compensator can reduce harmonics well, as seen from the harmonic values on Thursday, where before the Static Var Compensator was installed, the harmonics in phase R were 9.81%, phase S were 10.98%, and phase T were 9%.
Keywords :
harmonisa, Matlab/Simulink, Static Var Compensator.References :
- Adel A., Elbaset, et al. “IEC 61850 Communication Protocol with the Protection and Control Numerical Relays for Optimum Substation Automation System.” Journal of Engineering Science and Technology Review, vol. 13, no. 2, Apr. 2020, pp. 1–12
- Harmika, A. Sholichan, and L. Assaffat, “Measurement and Analysis of Load Imbalance and Electric Power Quality on 865 KVA Transformer at Universitas Muhammadiyah Semarang,” Proceedings of Unimus National Seminar, vol. 3, no. 0, 2020.
- Sinaga, R. M. Siburian, and J. Sirait, “Analysis of the Effect of Harmonics on Electrical Load Operation,” UDA Journal of Energy Technology, vol. 9, no. 2, pp. 88-97, 2020.
- P. Tondok, L. S. Patras, and F. Lisi, “Design of 125 kVA Distribution Transformer,” Journal of Electrical and Computer Engineering, vol. 8, no. 2, pp. 83–92, Aug. 2019, doi: https://doi.org/10.35793/jtek.v8i2.24895.
- M. Eltamaly, A.-H. M. El-Sayed, Y. S. Mohamed, and A. N. A. Elghaffar, “A modified techniques of transmission system by static var compensation (SVC) for voltage control,” in 2019 8th International Conference on Modeling Simulation and Applied Optimization (ICMSAO), 2019, pp. 1–6.
- USMAN and NURADDEEN MAGAJI, “SIMULATION OF SHUNT ACTIVE POWER FILTER BASED FUZZY LOGIC CONTROLLER FOR MINIMIZATION OF TOTAL HARMONIC DISTORTION,” International Journal of Applied and Advanced Engineering Research, 2023.
- Ramadhan, K. Yonathan, I. M. Ardita, F. H. Jufri and A. R. Utomo, “Voltage Stability Improvement Using Load Shedding and STATIC VAR COMPENSATOR (SVC): Study Case of Senayan-Sambas Power System,” 2019 IEEE International Conference on Innovative Research and Development (ICIRD), Jakarta, Indonesia, 2019, pp. 1-5.
- Turan, O., & Sarı, Y. (2021). Modelling a Static Var Compensator consist of TCR and TSC. Turkish Journal of Science and Technology, 16(1), 11-21.
- R. Maulana, “Analysis of Harmonic Occurrence in Variable Frequency Drives and Its Impact on Three-Phase Induction Motor Speed Control,” Unila.ac.id, 2025.
- P Harahap and B Oktrialdi, “Harmonisa in defibrillator equipment (DC Shock)using simulink Matlab,” IOP Conference Series Materials Science and Engineering, vol. 821, no. 1, pp. 012025–012025, Apr. 2020, doi: https://doi.org/10.1088/1757-899x/821/1/012025
- Jannah and R. Putri, “Penggunaan Single Tuned Filter Untuk Memperkecil Harmonisa yang Ditimbulkan Oleh Beban Non Linier Pada Transformator 400 kVA,” Proceeding Seminar Nasional Politeknik Negeri Lhokseumawe, vol. 2, no. 1, pp. 116 – 122, 2018.
- Hermawan, Mudjiono, C. Wiharya, and S. Seftiana, “Analysis of Load Balance and Harmonics at Graha Polinema, State Polytechnic of Malang,” Elposys: Journal of Electrical Systems, vol. 8, no. 3, pp. 47–52, Nov. 2021, doi: https://doi.org/10.33795/elposys.v8i3.76.
- “IEEE Standard for Harmonic Control in Electric Power Systems,” in IEEE Std 519-2022 (Revision of IEEE Std 519-2014) , vol., no., pp.1-31, 5 Aug. 2022, doi: 10.1109/IEEESTD.2022.9848440.
- Belati, E. A., Nascimento, C. F., de Faria, H., Watanabe, E. H., & Padilha Feltrin, A. (2018). Allocation of Static Var Compensator in Electric Power Systems Considering Different Load Levels. Journal of Control, Automation and Electrical Systems
- Irreza Naderipouret al., “Optimal designing of Static Var Compensator to improve voltage profile of power system using fuzzy logic control,” Optimal designing of Static Var Compensator to improve voltage profile of power system using fuzzy logic control, vol. 192, pp. 116665–116665, Feb. 2020
- A. Susilo, Transient Stability Analysis of Electric Power Systems Using Static Var Compensator, Samarinda, East Kalimantan: Rizky Aprylianto Susilo, 2018.