Abstract :
The present paper aims to analyze the water quality from the samples collected from the periphery of one of the cement plants located in Bhilai. Three different samples were collected in the summer season, covering the area around the cement plant considered. The samples were characterized by means of physicochemical parameters such as pH, TDS (mg/L), Turbidity (NTU), Total alkalinity (mg/L), Chloride (mg/L), Total hardness (mg/L), Fluoride (mg/L), and Nitrate (mg/L). The Water Quality Index (WQI) for the 03 samples collected was done and was found to be 166.264, 22.207, and 46.997, respectively. The dependency of WQI on various physicochemical parameters, along with the interdependency between the individual parameters, was analyzed using the loading plot obtained using Principal Component Analysis (PCA). It could be noticed that pH and fluoride contribute more to WQI in comparison to the other parameters included in this study. Z-score variance was also plotted to analyze the comparative stretching of the values of various individual parameters recorded. In addition, microbiological analysis was conducted using serial dilution, culturing, Gram staining, and biochemical testing. The presence of Bacillus spp, Escherichia coli, Klebsiella spp, Micrococcus spp, Pseudomonas spp., and Staphylococcus aureus was detected, indicating microbial contamination and possible health risks.
Keywords :
bacteria, Cement Industry, PCA, Physicochemical, Soil, WQIReferences :
- Masindi, K.L. Muedi, Environmental contamination by heavy metals, in: Heavy Metals, InTech, 2018.
- H. Walker, R.M. Sibly, S.P. Hopkin, D.B.P., in: Principles of Ecotoxicology; Group, T. And F., Ed.; 4th Edition, CRC Press, 2012.
- E. Martin, E.A. Johnson, Biogeosciences survey: studying interactions of the biosphere with the lithosphere, hydrosphere and atmosphere, Prog. Phys. Geogr. 36, 833–852 (2012).
- Briffa, E. Sinagra and R. Blundell, Heavy metal pollution in the environment and their toxicological effects on humans, Heliyon, 6(9), e04691 (2020).
- ACC Limited. (2015). Summary Environmental Impact Assessment Report: Capacity Enhancement of Jamul Cement Works Limestone Mine from 1.8 MTPA to 3.0 MTPA, Mining Lease Area 269.95 ha & Installation of 1500 TPH Crusher at Villages: Jamul, Dhaur, and Kurud, Tehsil & District Durg (Chhattisgarh).
- A. Siddiqui, R.N. Shukla, and Akbar Ziauddin, Impact of Cement Industry on the ground water quality – a Case Study, Journal of Industrial Pollution Control 27(2):133-137 (2011)
- https://www.epa.gov/pm-pollution/health-and-environmental-effects-particulate-matter-pm (accessed on 28.07.2024)
- AH Linton, JF Timoney and M Hinton, The ecology of chloramphenicol-resistance in Salmonella typhimurium and Escherichia coli in calves with endemic Salmonella infection. J. Appl. Bacteriol. 50: 115-129 (2018)
- WO Pipes WO, Bacterial indicators of pollution. CRC Press, Inc. Boca Ration, Florida, USA. Pp 174 (1982)
- J. Pelczer, E.C.S. Chan, and N.R. Krieg, Microbiology. 5th Edition. New Delhi Tata McGraw Hill Inc. New York. 663 – 664 (1993)
- Rajiv, A. S. Hasna, M. Kamaraj, S. Rajeshwam and R. Balgi, Comparative Physicochemical and Microbial Analysis of Various Pond Waters in Coimbatore District, Tamil Nadu, India. Annals of Biological Research, 3 (7):3533-3540 (2012)
- BIS, I.S.D.W.S., Bureau of Indian Standards. New Delhi, 2–3 (2012)
- D. Siriwardhana, D. I. Jayaneththi, R. D. Herath, R. K. Makumbura ,H. Jayasinghe , M. B. Gunathilake , H. Md. Azamathulla ,K. Tota-Maharaj and U. Rathnayake, A Simplified Equation for Calculating the Water Quality Index (WQI), Kalu River, Sri Lanka by, Sustainability, 15(15), 12012 (2023).
- Thakur, S. Karmakar, and R. Shrivastava, Hybrid deep learning algorithms for forecasting air quality index using dimension reduction technique in search of precise results, International Journal of Information Technology, 15, 3181–3187 (2023).
- World Health Organization, Guidelines for Drinking Water Quality, Volume I, II and III, World Health Organizations, Geneva (1993)
- Chung, S. Y., Venkatramanan, S., Park, N., Rajesh, R., Ramkumar, T., & Kim, B. W. (2015). An assessment of selected hydrochemical parameter trend of the Nakdong River water in South Korea, using time series analyses and PCA. Environmental Monitoring and Assessment, 187(4192). https://doi.org/10.1007/s10661-014-4192-9
- Bureau of Indian Standards. (1983). IS 3025 (Part 4): Methods of sampling and test (physical and chemical) for water and wastewater – Colour. New Delhi, India: Bureau of Indian Standards.
- Bureau of Indian Standards. (1984). IS 3025 (Part 8): Methods of sampling and test (physical and chemical) for water and wastewater – Taste rating. New Delhi, India: Bureau of Indian Standards.
- Bureau of Indian Standards. (1984). IS 3025 (Part 16): Methods of Sampling and Test (Physical and Chemical) for Water and Wastewater – Filterable Residue (Total Dissolved Solids). New Delhi: BIS. (Reaffirmed 2002)
- APHA (2017). Standard Methods for the Examination of Water and Wastewater, 23rd Edition. American Public Health Association
- Garrity, G. M. (Ed.). (2005). Bergey’s Manual of Systematic Bacteriology: Volume 2 – The Proteobacteria (Part A and B). New York, NY: Springer.
- Cappuccino, J. G., & Welsh, C. (2019). Microbiology: A Laboratory Manual (11th ed.). Pearson Education.
- Cheesbrough, M. (2006). District Laboratory Practice in Tropical Countries, Part 2. Cambridge University Press.
- Garrity, G. M. (Ed.). (2005). Bergey’s Manual of Systematic Bacteriology (Vols. 2–5). Springer.
- MacFaddin, J. F. (2000). Biochemical Tests for Identification of Medical Bacteria (3rd ed.). Lippincott Williams & Wilkins.
- Tortora, G. J., Funke, B. R., & Case, C. L. (2020). Microbiology: An Introduction (13th ed.). Pearson.
- IS:3025 (part 4) – 1983 (Reaffirmed 2002) – Methods of Sampling and Test (Physical and chemical) for water and Waste Water: Colour
- IS 3025 (P-26)-1986
- IS: 3025 (Part 24) – 1986 (Reaffirmed 1992) – Methods of Sampling and Test (Physical and chemical) for water and Waste Water: Sulphate.
- IS: 3025 (Part 23) – 1986 (Reaffirmed 2003)- Methods of Sampling and Test (Physical and chemical) for water and Waste Water: Alkalinity
- IS: 3025 (Part 21) – 1983 (Reaffirmed 2002) – Methods of Sampling and Test (Physical and chemical) for water and Waste Water: Total Hardness
- IS: 3025 (Part 60) – 2008 Methods of Sampling and Test (Physical and chemical) for water and Waste Water: Fluoride
- IS: 3025 (Part 46) – 1994 Methods of Sampling and Test (Physical and chemical) for water and Waste Water
- APHA 4500 NO3

